Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Neuroradiol ; 51(1): 16-23, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37308338

RESUMEN

BACKGROUND AND PURPOSE: Diffuse low-grade gliomas (DLGG) are characterized by a slow and continuous growth and always evolve towards an aggressive grade. Accurate prediction of the malignant transformation is essential as it requires immediate therapeutic intervention. One of its most precise predictors is the velocity of diameter expansion (VDE). Currently, the VDE is estimated either by linear measurements or by manual delineation of the DLGG on T2 FLAIR acquisitions. However, because of the DLGG's infiltrative nature and its blurred contours, manual measures are challenging and variable, even for experts. Therefore we propose an automated segmentation algorithm using a 2D nnU-Net, to 1) gain time and 2) standardize VDE assessment. MATERIALS AND METHODS: The 2D nnU-Net was trained on 318 acquisitions (T2 FLAIR & 3DT1 longitudinal follow-up of 30 patients, including pre- & post-surgery acquisitions, different scanners, vendors, imaging parameters…). Automated vs. manual segmentation performance was evaluated on 167 acquisitions, and its clinical interest was validated by quantifying the amount of manual correction required after automated segmentation of 98 novel acquisitions. RESULTS: Automated segmentation showed a good performance with a mean Dice Similarity Coefficient (DSC) of 0.82±0.13 with manual segmentation and a substantial concordance between VDE calculations. Major manual corrections (i.e., DSC<0.7) were necessary only in 3/98 cases and 81% of the cases had a DSC>0.9. CONCLUSION: The proposed automated segmentation algorithm can successfully segment DLGG on highly variable MRI data. Although manual corrections are sometimes necessary, it provides a reliable, standardized and time-winning support for VDE extraction to asses DLGG growth.


Asunto(s)
Glioma , Procesamiento de Imagen Asistido por Computador , Humanos , Estudios de Seguimiento , Procesamiento de Imagen Asistido por Computador/métodos , Glioma/diagnóstico por imagen , Glioma/patología , Imagen por Resonancia Magnética/métodos , Algoritmos
2.
Mov Disord ; 35(1): 142-150, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31518459

RESUMEN

BACKGROUND: Mitochondrial membrane protein-associated neurodegeneration is an autosomal-recessive disorder caused by C19orf12 mutations and characterized by iron deposits in the basal ganglia. OBJECTIVES: The aim of this study was to quantify iron concentrations in deep gray matter structures using quantitative susceptibility mapping MRI and to characterize metabolic abnormalities in the pyramidal pathway using 1 H MR spectroscopy in clinically manifesting membrane protein-associated neurodegeneration patients and asymptomatic C19orf12 gene mutation heterozygous carriers. METHODS: We present data of 4 clinically affected membrane protein-associated neurodegeneration patients (mean age: 21.0 ± 2.9 years) and 9 heterozygous gene mutation carriers (mean age: 50.4 ± 9.8 years), compared to age-matched healthy controls. MRI assessments were performed on a 7.0 Tesla whole-body system, consisting of whole-brain gradient-echo scans and short echo time, single-volume MR spectroscopy in the white matter of the precentral/postcentral gyrus. Quantitative susceptibility mapping, a surrogate marker for iron concentration, was performed using a state-of-the-art multiscale dipole inversion approach with focus on the globus pallidus, thalamus, putamen, caudate nucleus, and SN. RESULTS AND CONCLUSION: In membrane protein-associated neurodegeneration patients, magnetic susceptibilities were 2 to 3 times higher in the globus pallidus (P = 0.02) and SN (P = 0.02) compared to controls. In addition, significantly higher magnetic susceptibility was observed in the caudate nucleus (P = 0.02). Non-manifesting heterozygous mutation carriers exhibited significantly increased magnetic susceptibility (relative to controls) in the putamen (P = 0.003) and caudate nucleus (P = 0.001), which may be an endophenotypic marker of genetic heterozygosity. MR spectroscopy revealed significantly increased levels of glutamate, taurine, and the combined concentration of glutamate and glutamine in membrane protein-associated neurodegeneration, which may be a correlate of corticospinal pathway dysfunction frequently observed in membrane protein-associated neurodegeneration patients. © 2019 International Parkinson and Movement Disorder Society.


Asunto(s)
Encéfalo/patología , Hierro/metabolismo , Proteínas Mitocondriales/genética , Mutación/genética , Encéfalo/metabolismo , Humanos , Imagen por Resonancia Magnética/métodos , Proteínas de la Membrana/genética , Mitocondrias/metabolismo , Membranas Mitocondriales/metabolismo
3.
Neuroimage ; 172: 562-574, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29421323

RESUMEN

The neuromatrix, or "pain matrix", is a network of cortical brain areas which is activated by noxious as well as salient somatosensory stimulation. This has been studied in mice and humans using blood oxygenation level-dependent (BOLD) fMRI. Here we demonstrate that BOLD effects observed in the murine neuromatrix in response to salient somatosensory stimuli are prone to reflect mean arterial blood pressure (MABP) changes, rather than neural activity. We show that a standard electrostimulus typically used in murine somatosensory fMRI can induce substantial elevations in MABP. Equivalent drug-induced MABP changes - without somatosensory stimulation - evoked BOLD patterns in the neuromatrix strikingly similar to those evoked by electrostimulation. This constitutes a serious caveat for murine fMRI. The regional specificity of these BOLD patterns can be attributed to the co-localization of the neuromatrix with large draining veins. Based on these findings we propose a cardiovascular support mechanism whereby abrupt elevations in MABP provide additional energy supply to the neuromatrix and other essential brain areas in fight-or-flight situations.


Asunto(s)
Presión Sanguínea/fisiología , Encéfalo/fisiopatología , Nocicepción/fisiología , Dolor Nociceptivo/fisiopatología , Animales , Mapeo Encefálico/métodos , Estimulación Eléctrica , Potenciales Evocados Somatosensoriales/fisiología , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Ratones , Ratones Endogámicos C57BL
4.
Magn Reson Med ; 80(2): 672-684, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29327365

RESUMEN

PURPOSE: The aim of this study was to achieve millimeter spatial resolution sodium in vivo MRI of the human eye at 7 T using a dedicated six-channel transceiver array. We present a detailed description of the radiofrequency coil design, along with electromagnetic field and specific absorption ratio simulations, data validation, and in vivo application. METHODS: Electromagnetic field and specific absorption ratio simulations were performed. Transmit field uniformity was optimized by using a multi-objective genetic algorithm. Transmit field mapping was conducted using a phase-sensitive method. An in vivo feasibility study was carried out with 3-dimensional density-adapted projection reconstruction imaging technique. RESULTS: Measured transmit field distribution agrees well with the one obtained from simulations. The specific absorption ratio simulations confirm that the radiofrequency coil is safe for clinical use. Our radiofrequency coil is light and conforms to an average human head. High spatial resolution (nominal 1.4 and 1.0 mm isotropic) sodium in vivo images of the human eye were acquired within scan times suitable for clinical applications (∼ 10 min). CONCLUSIONS: Three most important eye compartments in the context of sodium physiology were clearly delineated in all of the images: the vitreous humor, the aqueous humor, and the lens. Our results provide encouragement for further clinical studies. The implications for research into eye diseases including ocular melanoma, cataract, and glaucoma are discussed. Magn Reson Med 80:672-684, 2018. © 2018 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Ojo/diagnóstico por imagen , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Sodio/química , Adulto , Diseño de Equipo , Femenino , Humanos , Masculino , Fantasmas de Imagen
6.
Magn Reson Med ; 78(4): 1533-1546, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-27851881

RESUMEN

PURPOSE: Proton radiation therapy (PRT) is a standard treatment of uveal melanoma. PRT patients undergo implantation of ocular tantalum markers (OTMs) for treatment planning. Ultra-high-field MRI is a promising technique for 3D tumor visualization and PRT planning. This work examines MR safety and compatibility of OTMs at 7.0 Tesla. METHODS: MR safety assessment included deflection angle measurements (DAMs), electromagnetic field (EMF) simulations for specific absorption rate (SAR) estimation, and temperature simulations for examining radiofrequency heating using a bow-tie dipole antenna for transmission. MR compatibility was assessed by susceptibility artifacts in agarose, ex vivo pig eyes, and in an ex vivo tumor eye using gradient echo and fast spin-echo imaging. RESULTS: DAM (α < 1 °) demonstrated no risk attributed to magnetically induced OTM deflection. EMF simulations showed that an OTM can be approximated by a disk, demonstrated the need for averaging masses of mave = 0.01 g to accommodate the OTM, and provided SAR0.01g,maximum = 2.64 W/kg (Pin = 1W) in OTM presence. A transfer function was derived, enabling SAR0.01g estimation for individual patient scenarios without the OTM being integrated. Thermal simulations revealed minor OTM-related temperature increase (δT < 15 mK). Susceptibility artifact size (<8 mm) and location suggest no restrictions for MRI of the nervus opticus. CONCLUSION: OTMs are not a per se contraindication for MRI. Magn Reson Med 78:1533-1546, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Melanoma/diagnóstico por imagen , Melanoma/radioterapia , Terapia de Protones/normas , Tantalio/análisis , Neoplasias de la Úvea/diagnóstico por imagen , Neoplasias de la Úvea/radioterapia , Animales , Calor , Humanos , Seguridad del Paciente , Fantasmas de Imagen , Terapia de Protones/métodos , Porcinos , Tantalio/química
7.
NMR Biomed ; 29(9): 1173-97, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-25706103

RESUMEN

The objective of this study was to document and review advances and groundbreaking progress in cardiac and body MR at ultrahigh fields (UHF, B0 ≥ 7.0 T) with the goal to attract talent, clinical adopters, collaborations and resources to the biomedical and diagnostic imaging communities. This review surveys traits, advantages and challenges of cardiac and body MR at 7.0 T. The considerations run the gamut from technical advances to clinical opportunities. Key concepts, emerging technologies, practical considerations, frontier applications and future directions of UHF body and cardiac MR are provided. Examples of UHF cardiac and body imaging strategies are demonstrated. Their added value over the kindred counterparts at lower fields is explored along with an outline of research promises. The achievements of cardiac and body UHF-MR are powerful motivators and enablers, since extra speed, signal and imaging capabilities may be invested to overcome the fundamental constraints that continue to hamper traditional cardiac and body MR applications. If practical obstacles, concomitant physics effects and technical impediments can be overcome in equal measure, sophisticated cardiac and body UHF-MR will help to open the door to new MRI and MRS approaches for basic research and clinical science, with the lessons learned at 7.0 T being transferred into broad clinical use including diagnostics and therapy guiding at lower fields. Copyright © 2015 John Wiley & Sons, Ltd.


Asunto(s)
Técnicas de Imagen Cardíaca/instrumentación , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagen por Resonancia Magnética/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Imagen de Cuerpo Entero/instrumentación , Algoritmos , Técnicas de Imagen Cardíaca/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Imagen de Cuerpo Entero/métodos
8.
Invest Radiol ; 50(5): 309-21, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25612144

RESUMEN

OBJECTIVES: This study is designed to examine the feasibility of diffusion-sensitized multishot split-echo rapid acquisition with relaxation enhancement (RARE) for diffusion-weighted ophthalmic imaging free of geometric distortions at 3.0 and 7.0 T in healthy volunteers and patients with intraocular masses. MATERIALS AND METHODS: A diffusion-sensitized multishot split-echo RARE (ms-RARE) variant is proposed as an alternative imaging strategy for diffusion-weighted imaging. It is compared with standard single-shot echo planar imaging (EPI) and readout-segmented EPI in terms of geometric distortions in a structure phantom as well as in vivo at 3.0 and 7.0 T. To quantify geometric distortions, center of gravity analysis was carried out. Apparent diffusion coefficient (ADC) mapping in a diffusion phantom was performed to verify the diffusion sensitization within ms-RARE. An in vivo feasibility study in healthy volunteers (n = 10; mean age, 31 ± 7 years; mean body mass index, 22.6 ± 1.7 kg/m²) was conducted at 3.0 and 7.0 T to evaluate clinical feasibility of ms-RARE. As a precursor to a broader clinical study, patients (n = 6; mean age, 55 ± 12 years; mean body mass index, 27.5 ± 4.7 kg/m²) with an uveal melanoma and/or retinal detachment were examined at 3.0 and 7.0 T. In 1 case, the diseased eye was enucleated as part of the therapy and imaged afterward with magnetic resonance microscopy at 9.4 T. Macrophotography and histological investigation was carried out. For qualitative assessment of the image distortion, 3 independent readers reviewed and scored ms-RARE in vivo images for all subjects in a blinded reading session. Statistical significance in the difference of the scores (a) obtained for the pooled ms-RARE data with b = 0 and 300 s/mm² and (b) for the 3 readers was analyzed using the nonparametric Mann-Whitney test. RESULTS: The assessment of geometric integrity in phantom imaging revealed the ability of ms-RARE to produce distortion-free images. Unlike ms-RARE, modest displacements (2.3 ± 1.4 pixels) from the fast low angle shot imaging reference were observed for readout-segmented EPI, which were aggravated for single-shot EPI (8.3 ± 5.7 pixels). These observations were confirmed in the in vivo feasibility study including distortion-free diffusion-weighted ophthalmic images with a 0.5 × 0.5 × 5 mm³ spatial resolution at 3.0 T and as good as 0.2 × 0.2 × 2 mm³ at 7.0 T. The latter represents a factor of 40 enhancement in spatial resolution versus clinical protocols recently reported for diffusion-weighted imaging of the eye at 1.5 T. Mean ADC values within the vitreous body were (2.91 ± 0.14) × 10⁻³ mm²/s at 3.0 T and (2.93 ± 0.41) × 10⁻³ mm²/s at 7.0 T. Patient data showed severe retinal detachment in the anatomical images. Whereas the tumor remained undetected in T1-weighted and T2-weighted imaging at 3.0/7.0 T, in vivo ADC mapping using ms-RARE revealed the presence of a uveal melanoma with a significant contrast versus the surrounding subretinal hemorrhage. This observation was confirmed by high-resolution ex vivo magnetic resonance microscopy and histology. Qualitative analysis of image distortion in ms-RARE images obtained for all subjects yielded a mean ± SD image quality score of 1.06 ± 0.25 for b = 0 s/mm² and of 1.17 ± 0.49 for b = 300 s/mm². No significant interreader differences were observed for ms-RARE with a diffusion sensitization of b = 0 s/mm² and 300 s/mm². CONCLUSIONS: This work demonstrates the capability of diffusion-sensitized ms-RARE to acquire high-contrast, high-spatial resolution, distortion-free images of the eye and the orbit at 3.0 and 7.0 T. Geometric distortions that are observed for EPI-based imaging approaches even at lower field strengths are offset by fast spin-echo-based imaging techniques. The benefits of this improvement can be translated into the assessment of spatial arrangements of the eye segments and their masses with the ultimate goal to provide guidance during diagnostic treatment of ophthalmological diseases.


Asunto(s)
Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Melanoma/patología , Desprendimiento de Retina/patología , Neoplasias de la Úvea/patología , Técnicas de Diagnóstico Oftalmológico , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Proyectos Piloto , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA